Articles

Searching...

No articles found.

Search in products: ""

No documents found.

CS AM14F1VU-P2

CS AM14F1VU-P2

CS AM series safety module, motor standstill detection

Key information

Communication port
Not programmable
Connection type
Screw terminals
Function
Module for motor standstill monitoring, up to Cat. 4, SIL 3, PL e
Output contacts
2 NO safety contacts, 1 NC contact
Programme P2
Voltage range 40 mV – 500 mV, phase simultaneity time on start-up = 3 s, phase simultaneity time on stop = deactivated, safety output delay on = 3 s
Supply voltage
24 Vdc

Documentation

Quality marks

Products in the same line

CS AM14F1VU-P2 Request information