CS AM14F1XU-P6

CS AM14F1XU-P6

CS AM series safety module, motor standstill detection

Key information

Communication port
Not programmable
Function
Module for motor standstill monitoring, up to Cat. 4, SIL 3, PL e
Output contacts
2 NO safety contacts, 1 NC contact
Programme P6
Voltage range 40 mV – 500 mV, phase simultaneity time on start-up = 3 s, phase simultaneity time on stop = deactivated, safety output delay on = 1,5 s
Supply voltage
24 Vdc